The Data

As all the testing in this round up was performed with the exact same equipment, using the exact same methods I have decided to keep each radiators page uncluttered by posting our testing methodology, test set-ups and equipment used in a single location. To see exactly how the tests were carried out, details of the test set ups and equipment used, please head back to the RRU’15 Test Equipment Page.

Restriction Test

It’s generally agreed that radiators are one of, if not the least restrictive components in the water cooling loop. There are some exceptions however, so this must still be verified through testing:

sr1_5

The above photo is for referencing the restriction test bench. The XSPC RX360 v2 is not loaded so please disregard the data in the picture as it does not relate to the RX v2.

Here is the raw data at the tested flow rates, displaying the measured Differential Pressure across the RX v2 as flow rate was increased.

rx14

The table numbers indicate that the RX v2 is a very low restriction radiator. However numbers in isolation can only tell half the story. By plotting against other components it more easily shows the whole story. I have decided to use a HeatKiller 3.0 CPU block as the reference in these plots for two reasons. Firstly there is no chance of the plot being cluttered by curves overlapping and secondly it gives a reference point against a fairly common loop component of average restriction. For radiator to radiator restriction comparisons please see the RRU’15 data pages. As with all the radiator restriction plots I have limited the maximum flow rate displayed to 2.0 GPM as I suspect there are very few systems that operate above 2.0 GPM. For more information on how to read a restriction plot check out our guide.

RX V2 - Restriction Chart

Now that we see how the RX v2 scales with flow we can take a few of those data points and compare vs the competition:

RX V2 - Restriction Comparison 0.5

RX V2 - Restriction Comparison 1.0

RX V2 - Restriction Comparison 1.5

This confirms that the RX v2 has a very low restriction level.

Onwards to Thermal Performance!

1 COMMENT

  1. […] Alphacool Monsta 360 Radiator Alphacool ST30 360 Radiator AquaComputer Airplex Radical Copper 360 Radiator AquaComputer AMS 360 Radiator Coolgate CG 360 Radiator EK SE 360 Radiator EK XTX 360 Radiator EK XE 360 Radiator Hardware Labs Black Ice GTX 360 Radiator Hardware Labs SR2 360 Radiator Phobya G-Changer HPC 360 Radiator XSPC RX v2 360 Radiator […]

Comments are closed.