The Data

As all the testing in this round up was performed with the exact same equipment, using the exact same methods I have decided to keep each radiators page uncluttered by posting our testing methodology, test set-ups and equipment used in a single location. To see exactly how the tests were carried out, details of the test set ups and equipment used, please head back to the RRU’15 Test Equipment Page.

Restriction Test

It’s generally agreed that radiators are one of, if not the least restrictive components in the water cooling loop. There are some exceptions however, so this must still be verified through testing:

Phobya Flow Testing - Lr Edited with B&W-1

In these shots the Iwaki RD30 is pushing 3.0 gpm through the G-Changer which is returning a differential pressure of 0.96 PSI.

Phobya Flow Testing - Lr Edited with B&W-2

Here is the raw data at the tested flow rates, displaying the measured Differential Pressure across the radiator as flow rate was increased.

phobya5

The table numbers indicate that the G-Changer V2 is a very low restriction radiator.  However numbers in isolation can only tell half the story. By plotting against other components it more easily shows the whole story. I have decided to use a HeatKiller 3.0 CPU block as the reference in these plots for two reasons. Firstly there is no chance of the plot being cluttered by curves overlapping and secondly it gives a reference point against a fairly common loop component of average restriction. For radiator to radiator restriction comparisons please see the RRU’15 data pages. As with all the radiator restriction plots I have limited the maximum flow rate displayed to 2.0 GPM as I suspect there are very few systems that operate above 2.0 GPM. For more information on how to read a restriction plot check out our guide.

G-C V2 - Restriction Chart

Now that we know how the G-Changer reacts to flow, we can take a couple of those data points and compare to the competition:

G-C V2 - Restriction Comparison 0.5

G-C V2 - Restriction Comparison 1.0

G-C V2 - Restriction Comparison 1.5

As expected the G-Changer measures almost identically to the UT60.  Both are very low restriction radiators that can be used multiple times in a loop without much concern for flow dropping.

Onwards to Thermal Performance!